Quantcast
Channel: VMware Communities : All Content - All Communities
Viewing all articles
Browse latest Browse all 175326

Error: Module 'Monitor' power on failed. Failed to start the virtual machine.

$
0
0

Hello,

 

Edit:

I did install Valorant before having the problem.

 

 

So I have been trying to create virtual machine with VMware workstation 15 pro and was not able to power it on.

 

Here is the message I get when i use "power on this virtual machine":

This virtual machine failed to switch to 64 bit mode. This failure might be due to a lack of available memory on the host.

Module 'Monitor' power on failed.

Failed to start the virtual machine.

 

vm1png.png

 

I am using:

- Ubuntu LTS 18.04 iso

 

My computer has:

- Windows 10 Education

- 16Gb RAM

- More than 100Gb of free space (hard disk)

- Motherboard: an asrock phantom

- CPU: amd ryzen 5 3600x

- Antivirus: Windows defender

 

I have tried:

- Rebooting

- Updating windows (normal updates)

- Keeping the default parameters while creating the vm

- Limiting the RAM to 250mb

- limiting the hard disk to 1Gb

- Checking that SVM and SMT are enabled for virtualization in the Bios

- Using VMware workstation Player 15, same issue

- Using virtualbox with the same configuration, it is working

- enabling/disablings Windows Hyper-V

- Disabling windows defender my firewalls

 

Here is my vmware.log file:

https://easyupload.io/e9r0n7

Here are the last lines if you do not wish to dl the entire file:

2020-04-19T19:23:13.805+02:00| vmx| I125: Host AMD-V Capabilities:

2020-04-19T19:23:13.805+02:00| vmx| I125: SVM Revision:           1

2020-04-19T19:23:13.805+02:00| vmx| I125: ASIDs Supported:        32768

2020-04-19T19:23:13.805+02:00| vmx| I125: Nested Paging:          yes

2020-04-19T19:23:13.805+02:00| vmx| I125: SVM GMET:               yes

2020-04-19T19:23:13.805+02:00| vmx| I125: LBR Virtualization:     yes

2020-04-19T19:23:13.805+02:00| vmx| I125: SVM Lock:               yes

2020-04-19T19:23:13.805+02:00| vmx| I125: NRIP Save:              yes

2020-04-19T19:23:13.805+02:00| vmx| I125: TSC Rate MSR:           yes

2020-04-19T19:23:13.805+02:00| vmx| I125: VMCB Clean Bits:        yes

2020-04-19T19:23:13.805+02:00| vmx| I125: Flush by ASID:          yes

2020-04-19T19:23:13.805+02:00| vmx| I125: Decode Assists:         yes

2020-04-19T19:23:13.805+02:00| vmx| I125: Pause Filter:           yes

2020-04-19T19:23:13.805+02:00| vmx| I125: Pause Filter Threshold: yes

2020-04-19T19:23:13.805+02:00| vmx| I125: Monitor_PowerOn: HostedVSMP skew tracking is disabled

2020-04-19T19:23:13.805+02:00| vmx| I125: Loaded crosspage: .crosspage. Size = 4096 bytes.

2020-04-19T19:23:13.805+02:00| vmx| I125: vmm64-modules: [vmm.vmm64, vmce-vmce.vmm64, viommu-none.vmm64, vprobe-none.vmm64, hv-svm.vmm64, gphys-npt.vmm64, callstack-none.vmm64, swstats-none.vmm64, gi-none.vmm64, gmm-none.vmm64, ahci-ahci.vmm64, !ahciRegs=0x0, !ahciShared=0x1000, !e1000Shared=0x1c00, !vmSamples=0x2480, !theIOSpace=0x24c0, !ttGPPerVcpu=0x8800, {UseUnwind}=0x0, numVCPUsAsAddr=0x1, {SharedAreaReservations}=0x8840, {rodataSize}=0x20915, {textAddr}=0xfffffffffc000000, {textSize}=0x8b65e, <MonSrcFile>]

2020-04-19T19:23:13.805+02:00| vmx| I125: vmm64-vcpus:   1

2020-04-19T19:23:13.818+02:00| vmx| I125: Module 'Monitor' power on failed.

2020-04-19T19:23:13.818+02:00| vmx| I125: VMX_PowerOn: ModuleTable_PowerOn = 0

2020-04-19T19:23:13.818+02:00| vmx| I125: Vix: [mainDispatch.c:1163]: VMAutomationPowerOff: Powering off.

2020-04-19T19:23:13.819+02:00| vmx| I125: Win32U_GetFileAttributes: GetFileAttributesExW("C:\Users\X\Documents\Virtual Machines\Ubuntu 64-bit\Ubuntu 64-bit.vmpl", ...) failed, error: 2

2020-04-19T19:23:13.819+02:00| vmx| I125: Policy_SavePolicyFile: invalid arguments to function.

2020-04-19T19:23:13.819+02:00| vmx| I125: PolicyVMX_Exit: Could not write out policies: 15.

2020-04-19T19:23:13.819+02:00| vmx| I125: WORKER: asyncOps=0 maxActiveOps=0 maxPending=0 maxCompleted=0

2020-04-19T19:23:13.819+02:00| WinNotifyThread| I125: WinNotify thread exiting

2020-04-19T19:23:13.822+02:00| vmx| I125: Vix: [mainDispatch.c:4215]: VMAutomation_ReportPowerOpFinished: statevar=1, newAppState=1873, success=1 additionalError=0

2020-04-19T19:23:13.822+02:00| vmx| I125:

2020-04-19T19:23:13.822+02:00| vmx| I125+ Power on failure messages: This virtual machine failed to switch to 64 bit mode. This failure might be due to a lack of available memory on the host.

2020-04-19T19:23:13.822+02:00| vmx| I125+ Module 'Monitor' power on failed.

2020-04-19T19:23:13.822+02:00| vmx| I125+ Failed to start the virtual machine.

I cannot seem to find any related issues or solutions that fits my problem.

 

Thank you in advance for any help provided.