Word of warning for anyone starting a UEM migration, it appears that UEM can mess with PCoIP USB if it is left in a running but unconfigured state.
We installed UEM in a Gold master image and left the service to automatic startup, with no UEM GPO's were applied to the linked clone pools. (We were preparing for UEM migration/testing)
USB devices fail to attach in the initial login session, a reconnect on PCoIP allows the devices to pass through from the Zero client. The issue also seems to delay the attachment of Appvolumes appstacks. PCoIP server log reports:
LVL:1 RC: 0 SOFT_USB :VHUBLIB(error): GetUemStatus : Failed to open key path is Software\VMware, Inc.\VMware UEM\SessionData\1
LVL:1 RC: 0 SOFT_USB :VHUBLIB(error): The UEM component is still not ready yet
Workaround is to set the service to manual/disabled until UEM is required for a desktop pool. If UEM is enabled at login (say via the GP extension method), the issue does not occur. We didn't raise a case for this, but an interesting one anyway.
(UEM 9, Appvol 2.9, Horizon 7)